When the first cleanroom was tested instruments that counted the dust particles registered zero, causing Whitfield and others to assume they were broken, Whitfield said in The laminar-flow cleanroom created a work environment that was more than 1, times cleaner than the cleanrooms in use at the time.
A micron is equal to millionths of an inch. Eventually, Whitfield worked with NASA to provide techniques to sterilize spacecraft and assure planetary quarantines during missions to the moon and Mars. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corp.
With main facilities in Albuquerque, N. Sandia news media contact: Heather Clark, hclark sandia. Each zone, or column, of airflow is defined and has its own range in airspeed. This allows for higher speed barrier air columns to be utilized as an engineering solution to equipment that otherwise would have poor containment or product protection ratings.
Dilution flow is not the same as laminar air flow. The dilution flow principle is used in equipment such as filtered glove boxes. In these instances, HEPA-filtered air mixes with and dilutes interior airborne contaminants inside the glove box, and those contaminants are removed via a filtered exhaust system. After the contamination source has been sealed, the dilution rate—or air changes per minute—will determine how much time must lapse before materials can be removed from the main chamber.
While laminar air flow helps to reduce turbulence, turbulent flow encourages it by creating unintentional swirls of air that place particles randomly on surfaces within an enclosure. Turbulent flow can be disruptive to work that requires a dust-free environment and can lead to contamination. Obstructions, like items left inside enclosures, can create this unwanted turbulence.
About Labconco Careers Contact Us. Whitfield, W J. Brief history of laminar flow clean room systems. United States: N. Copy to clipboard. United States. In an initial model, Whitfield designed a workbench along one wall. Clean air entered the room from a bank of filters that were For example, cigarette smoke blown in one side comes out the other as clean air.
The air was circulated in the room at a rate of 4, cubic feet or about 10 changes of air per minute. The resulting linear speed of the air is slightly more than 1 mph, which is about the same as that felt walking through a still room. In a later modification, the air was passed down over the work area instead of across, letting gravity help carry troublesome particles into the floor, which was covered with grating. Filters underneath clean the air and it is circulated back around to re-enter the room.
When the first cleanroom was tested instruments that counted the dust particles registered zero, causing Whitfield and others to assume they were broken, Whitfield said in The laminar-flow cleanroom created a work environment that was more than 1, times cleaner than the cleanrooms in use at the time.
According to tests at the time, the laminar-flow cleanroom's work area contained an average of dust particles one-third of a micron in size or larger per cubic foot of air. A micron is equal to millionths of an inch. That's compared to average dust counts of more than 1 million particles per cubic foot of air in one of the best conventional cleanrooms in use at the time. Eventually, Whitfield worked with NASA to provide techniques to sterilize spacecraft and assure planetary quarantines during missions to the moon and Mars.
Explore further. More from Other Physics Topics. Use this form if you have come across a typo, inaccuracy or would like to send an edit request for the content on this page. For general inquiries, please use our contact form. For general feedback, use the public comments section below please adhere to guidelines.
Your feedback is important to us. However, we do not guarantee individual replies due to the high volume of messages. Your email address is used only to let the recipient know who sent the email. Neither your address nor the recipient's address will be used for any other purpose. The information you enter will appear in your e-mail message and is not retained by Phys.